( Reaffirmed 2005 ) IS : 771 ( Part 3,Sec 2 ) - 1985 hiian GLAZED PART 3 Standara' SPECIFICATION FOR FIRE-CLAY SANITARY APPLIANCES SPECIFIC Section REQUIREMENTS 2 Stall Urinals OF URINALS ( Third Revision ) Sanitary Appliances and Water Fittings Sectional Committee, BDC 3 Chairman SHRI K. D. MULEKAR Rapreunting Municipal Corporation Bombay of Greater Bombay, Members Central Public Health & Environmental Engineering Organization ( Ministry of Works & Housing ), New Delhi DEPUTY ADVISER ( PHE ) ( Alternate ) M/s Goverdhan Das P. A. ( Calcutta ), Calcutta SRRI J. R. AQQARWAL National Test House, Calcutta Saar S. K. BANERJEE SERI D. K. KANUN~O ( Alternate ) Central Glass & Ceramic Research Institute SHRI M. K. BASU ( CSIR ), Calcutta Uttar Pradesh Jal Nigam, Lucknow CHIEF ENQINEER SUPERINTENDINGENQINEER (Alp;;;;: Health Engineering CHIEB ENGINEER Department, Trivandrum SHRI K. RAMACIHANDRAN(Alternate ) Delhi Municipal Corporation, Delhi SERI J. D'CRVZ Srmr S. A. SWAMY ( Alternate) Engineer-in-Chief's Branch, Army Headquarters, SHRI B. R. N. G~JPTA New Delhi SHRI K. V. KRIBBNA~~VRTHY ( Alternate ) Municipal Corporation of Greater Bombay, HYDRAVLIC ENGINEER Bombay DEPVTY HYDRAVLI~ ENQINEER ( Alternate ) ADVISER ( Continued on puge 2 ) Q CopVright1988 STANDARDS INSTITUTION ' INDIAN This publication is protected under the Indian Copyright Act ( XIV of 1957) and reproduction in whole or in part by any means except with written permission of the publisher shall be deemed to be an infringement of copyright under the said Act. IS : 771 (Part 3/Set 2 ) - 1985 ( Cantinucdfiom page 1 ) Memkrs SHRI S. R. KSHIRS~QA~ Representing National Environmental Engineering Research Institute (CSIR), Nagpur SHRI A. W. DES~PBNDE (Alfern& ) SHRI K. LAKSHMINARAYANAN Hindustan Shipyard Ltd, Vishakhapatnam SERI A. SHARIFB ( AIt~rnatc ) DR A. V. R. RAO National Buildings Organization, New Delhi SHRI,J. SEN~UPTA ( Altcrnatc ) SARI A. K. SARKAR E.I.D. Parry ( India) Limited, Madras SRRI M. DOXAISWAMY ( Alternate ) Leader Engineering Works, Jallandhar SHKI D. K. SEA~AL SARI B. B. SIKKA ( ALternafc ) SENIOB CIVIL ENGINEER ( WATER MinisDt;;hiof Railway ( Railway Board ), New SUPPLY ) SHRI S. K. SHARX~A Central Building Research Institute ( CSIR ), Roorkee _ Maharashtra Water SUDD~V & Sewerage Board. SHRI M. N. SHEWADE New Bombay Hindustan Sanitaryware & Industries Limited, SHRI R. K. SOMANY Bahadurgarh SUPERINTENDINQ SURVEYOR OF Central Public Works Department, New Delhi WORKS ( NDZ ) SURVEYOR OF WORKS I ( NDZ ) ( Alternate ) Directorate General of Technical Development, SHRI R. THANJAN New Delhi SHRI M. M. ALIKHAN ( Alternate ) Directorate General of Supplies & Disposals, New SHRI T. N. UBOVEJA Delhi Director General, IS1 ( Ex-ojicie Member ) SHRI G. RAMAN, Director ( Civ Engg ) Secretary SHRI K. K. SHARJ~A Joint Director ( Civ Engg ), IS1 Domestic Sanitary Appliances and Accessories Subcommittee, Convener SHRI B. R. N. GUPTA Engineer-in-Chief ,New Delhi Branch, Army BDC 3 : 1 Headquarters, Members SHRI V. ANANTRANARAYANAN SHRI M. K. BASU CHIEF ENGINEER CHIEF ENGINEER ( SEWERAQE) DBPUTY CHIEF ENGINEER ( SEWERAGE ) ( Altcrnatc ) East India Ceramics, Vellore Central Glass & Ceramic ( CSIR ), Calcutta Tam&ayr;y Water Supply Municipal Corporation Bombay of Research & Drainage Greater Institute Board, Bombay, ( Continued on pega 7 ) IS : 771 ( Part J/Set 2) - 1985 Indian Standard GLAZED PART 3 SPECIFICATION FOR FIRE-CLAY SANITARY APPLIANCES SPECIFIC Section REQUIREMENTS 2 Stall Urinals OF URINALS ( Third Revision ) 0. FOREWORD 0.1 This Indian Standard ( Part 3/Set 2 ) ( Third Revision ) was adopted by the Indian Standards Institution on 31 July 1985, after the draft finalized by the Sanitary Appliances and Water Fittings Sectional Committee had been approved by the Civil Engineering Division Council. 0.2 This standard was first published in 1958 and subsequently revised This revision has been taken up to include an in 1963 and 1979. additional size of stall urinal also in use. The general requirements applicable to all appliances and specific requirements for different types of appliances have been covered in separate parts of the standard. This standard ( Part 3/Section 2 ) lays down the specific requirements of stall urinals. 0.3 In the formulation of this standard due weightage has been given to international coordination among the standards and practices prevailing in different countries in addition to relating it to the practices in the field in this country. 0.4 For the purpose of deciding whether a particular requirement of this standard is complied with, the final value, observed or calculated, expressing the result of a test or analysis, shall be rounded off in The number of significant places retained accordance with IS : 2-1960*. in the rounded off value should be the same as that of the specified value in this standard. 1. SCOPE 1.1 This standard ( Part 3/Set 2 ) lays down the sizes, construction, dimensions, tolerances and finish of stall urinals made of fire clay. ' `Rules for rounding off numerical valuer ( revised). 3 IS : 771 ( Part 3/Set 2. REQUIREMENTS 2 ) - 1985 2.1 General - The general requirements methods of test, and inspection shall conform 2.2 Type and Size -The in Table 1 (see Fig. 1 ). TABLE TYPE 1 mm 1 140 x ,160 x 400 1 TYPE for material, manufacture, to IS : 771 ( Part 1 )-1979*. shall be as given type and size of stall urinals AND SIZE OF STALL URINALS TYPE 2 mm 1 500 x 520 x 400 2.2.1 The stall urinals may be made in other sizes where so agreed to However, tolerances on between the manufacturer and the purchaser. dimensions shall be as specified.in this standard. 2.3 Construction -- Stall urinals shall be manufactured either as a single urinal or as a range of two or more urinals as specified by the purchaser. The inside surface of the urinals shall be regular and smooth throughout to ensure efficient flushing. The bottom of urinals shall have sufficient slope from the front towards the outlet such that there is efficient draining of the urine. 2.4 Dimensions and Tolerances shall be as given in Table 2. TABLE 2 DIMENSIONS - The dimensions and tolerances AND TOLERANCES OF STALL URINALS All dimensions in millimetres. A Type Type2 B c D E F 4 25 f G H 3 1 1 140 f 45 460 + 18 400 & 16 255 i- 10 100 f 1500f60 500-+204OOzk16 19Ozt 7 90f4 2 100 f 4 65 + 3.90 f 4 -0 35&2 80&3 65+3 90&4 -0 3. MARKING 3.1 Each stall urin&s prominent place with manufacturer. --( second revision ) . shall be clearly and indelibly marked at a the type, name and trade-mark of the *Specification for glazed fire-clay sanitary appliances: Part 1 General requirements 4 IS : 771 ( Part 3/Set 2 ) - 1985 SECTION D Xx L-1 G FIG.1 STALL URINAL 5 Is : 771( Part 3/Set 2 ) - 1985 3.1.1 Each stall urinal conforming to the requirements specified in this standard may also be marked with the ISI certification mark. NOTE - The use of the IS1 Certification Mark is governed by the provisions 06 the Indian Standards Institution (Certification Marks) Act and the Rules and Regulations made thereunder. The IS1 Mark on products covered by an Indian. Standard conveys the assurance that they have been produced to comply with the requirements of that standard under a well-defined system of inspection, testing and quality control which is devised and supervised by IS1 and operated by the producer. IS1 marked products are also continuously checked by IS1 for conformity Details of conditions under which a licence to that standard as a further safeguard. for the use of the IS1 Certification Mark may be granted to manufacturera or processors, may be obtained from the Indian Standards Institution. 4. SAMPLING 4.1 Sampling shall be done in accordance with IS : 9140-1985*. *Methods of sampling of vitreous and fire-clay 6 sanitary appliances (firJl rmision ). IS : 771 ( Part 3/Set 2 ) - 1985 (Continued from page 2 ) Members Rebresentinp SHRI J. D' CRUZ Municipal Corporation of Delhi, Delhi SRRI S. S. RAMRARHYANI f Altcrrrate 1 DEPUTY DIRECTOR ( ARCH ) Reskarch, .Designs & Standards Organization ( Mmutry of Railways ), Lucknow ASSISTAN.PDIRECTOR ( AROH ) ( Akernnle ) SHRI A. A. GAWPULE Parshuram Pottery Works Co Ltd, Thangadh SRRI RAJENDRA KUMAR ( Alternate 1 SHRI S. P. JAMES Public Health Department, Engineering Trivandrum SHRI K. RBXACAANDRAN ( Alternate 1 SHRI B. D. KOTHARI Madhusudan Ceramics, Ahmadabad SHRI M. S. BHATT ( Alternate ) SHRI K. V. KRISENAMURTEY Engineer-in-Chief's Branch, Army Headquarters, New Delhi Indian Plastics Limited, Bombay SHRI K. V. KRISENAN SHRI M. L. ANAND ( Alkrnate ) Roplas ( India ) Limited, Pune SERI J. LAKHANI SHRI E. D. SHAR,XA (Alternate ) SHRI B. K. MALRAN In personal capacity, ( 9 Jain Mandir Road, New Delhi ) SHRI B. S. MIRCEANDANI Phenoweld Polymer Pvt Ltd, Bombay SRRI P. R. GUPTA ( Alternate ) E. I. D. Parry ( India) Ltd, Madras SHRI A. K. SAREAR SHRI M. DORAISWAMY ( Alternate) Neiveli Ceramics & Refractories Ltd, Vadalur SHRI UMATOSH SARRAR M/s Sehgal & Co, New Delhi SHRI L. R. SEHQAL National Buildings Organization, New Delhi SHRI J. SENQUPTA SHRI 0. P. RATRA ( Alternate ) Centr$o~k$~ding Research Institute ( CSIR ), SHRI S. K. SHARMA SHRI R. K. SONANY Hindustan Sanitaryware & Industries Ltd, Bahadurgarh Central Public Works Department, New Delhi SVPERINTENDINQ SURVEYOR OB WORKS ( SWZ ) SURVEYOR OF WORKS ( NDZ j I Alternate `I SHRI G. K. TAKIER ' ' ' FGP Ltd, New Delhi SERI S. M. DASTUR ( Alternate ) Directorate General SHRX T. N. UBOVEJA New Delhi of Supplies & Disposals, 7 INTERNATIONAL Base Unita QUANTITY SYSTEM OF UNITS ( SI UNITS ) UNIT SYMBOL m kg S `4 K cd mol Length Mass Time Electric current Thermodynamic temperature * Luminous intensity Amount of substance Snpplementary QUANTITY Units metre kilogram second ampere kelvin candela mole UNIT SYMBOL rad sr Plane angle Solid angle Derived Force Energy Units radian steradian QUANTITY UNIT newton joule watt weber tesla hertz siemenn volt Pascal SI-MBOL J" W DEETNITION 1N 1 kg.m/sl Power FlUX Flux density Frequency Electric conductance Electromotive force Pressure, stress Wb T HZ S V Pa 1 N.m 1W -lJ/s 1 Wb1V.s 1 T = 1 Wb/ms 1 Hz - 1 c/r (s-l) 1S - 1 A/V 1 V - 1 W/A I Pa - 1 N/m' 1J -